NEWS

TSJINC 바이오 전문 서비스 브랜드입니다.

[Cloud-Clone 한국공식대리점] Assay Kits

작성자
관리자
작성일
2025-04-22
조회수
456




어스바이오는 Cloud-Clone 한국 공식 대리점입니다.

어스바이오는 Cloud-Clone 한국 공식 대리점으로서 모든 제품을 전문적으로 취급 및 공급하고 있습니다.

[ELISA Kit for Adenosine Diphosphate (ADP)]



 

  • Product No.CEB069Ge
  • Organism SpeciesPan-species (General) Same name, Different species.
  • Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
  • Test MethodCompetitive Inhibition
  • Assay Length2h
  • Detection Range18.52-1,500ng/mL
  • SensitivityThe minimum detectable dose of this kit is typically less than 6.25ng/mL.
  • DownloadInstruction Manual
  • UOM48T96T 96T*5 96T*10 96T*100

Specificity

This assay has high sensitivity and excellent specificity for detection of Adenosine Diphosphate (ADP).
No significant cross-reactivity or interference between Adenosine Diphosphate (ADP) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of Adenosine Diphosphate (ADP) and the recovery rates were calculated by comparing the measured value to the expected amount of Adenosine Diphosphate (ADP) in samples.

MatrixRecovery range (%)Average(%)
serum(n=5)92-105101
EDTA plasma(n=5)81-10499
heparin plasma(n=5)86-9689

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Adenosine Diphosphate (ADP) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Adenosine Diphosphate (ADP) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% 

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Adenosine Diphosphate (ADP) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample1:21:41:81:16
serum(n=5)96-105%79-104%97-105%94-101%
EDTA plasma(n=5)80-99%82-104%79-89%99-105%
heparin plasma(n=5)94-102%79-105%93-101%94-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

 

 

 


 

어스바이오(USBIO)는 Cloud-Clone 한국 공식 대리점입니다.
해당 제품에 대한 문의나 Cloud-Clone 제품의 견적 또는 문의사항이 있으시면 아래로 연락주시기 바랍니다.
Tel: 02-862-2816 / Email: bio@usbio.co.kr

이전

다음