| List of Degassing Inserts | |||
| Product: | Item Number: | Description: | Performance: |
| F15 | 924 005 | incl.
drip-off edge recommended for 1–25 L |
Typical
airflow at 12 mbar: 5.2 L / h Typical water entry pressure: 0.8 bar |
| F15 LOCK* | 924 006 | incl.
drip-off edge recommended for 1–25 L |
Typical
airflow at 12 mbar: 5.2 L / h Typical water entry pressure: 0.8 bar |
| F17 | 924 015 | incl.
drip-off edge & splash protection recommended for 25–60 L |
Typical
airflow at 12 mbar: 5.2 L / h Typical water entry pressure: 0.8 bar |
| F17 LOCK* | 924 016 | incl.
drip-off edge & splash protection recommended for 25–60 L |
Typical
airflow at 12 mbar: 5.2 L / h Typical water entry pressure: 0.8 bar |
| F17 HF | 924 055 | incl.
drip-off edge & splash protection with increased airflow recommended for 25–60 L |
Typical
airflow at 12 mbar: 15.2 L / h Typical water entry pressure: 0.3 bar |
| F17 LOCK* HF | 924 056 | incl.
drip-off edge & splash protection with increased airflow recommended for 25–60 L |
Typical
airflow at 12 mbar: 15.2 L / h Typical water entry pressure: 0.3 bar |
| F38 | 924 025 | incl.
splash protection recommended for 60–1,500 L |
Typical
airflow at 12 mbar: 72.8 L / h Typical water entry pressure: 0.8 bar |
| F38 LOCK* | 924 026 | incl.
splash protection recommended for 60–1,500 L |
Typical
airflow at 12 mbar: 72.8 L / h Typical water entry pressure: 0.8 bar |
| F38 LOCK* SN | 924 036 | incl.
splash protection with shortened neck recommended for 60–1,500 L |
Typical
airflow at 12 mbar: 72.8 L / h Typical water entry pressure: 0.8 bar |
| F38 HP | 924 027 | incl.
splash protection with increased water entry pressure recommended for 60–1,500 L |
Typical
airflow at 12 mbar: 21.1 L / h Typical water entry pressure: 3.0 bar |
| F38 LOCK* HP | 924 028 | incl.
splash protection with increased water entry pressure recommended for 60–1,500 L |
Typical
airflow at 12 mbar: 21.1 L / h Typical water entry pressure: 3.0 bar |
| F38 LOCK* SN HP | 924 039 | incl.
splash protection with shortened neck with increased water entry pressure recommended for 60–1,500 L |
Typical
airflow at 12 mbar: 21.1 L / h Typical water entry pressure: 3.0 bar |
| F38 HF | 924 065 | incl.
splash protection with increased airflow recommended for 60–1,500 L |
Typical
airflow at 12 mbar: 139 L / h Typical water entry pressure: 0.4 bar |
| F38 LOCK* HF | 924 066 | incl.
splash protection with increased airflow recommended for 60–1,500 L |
Typical
airflow at 12 mbar: 139 L / h Typical water entry pressure: 0.4 bar |
| F38 LOCK* SN HF | 924 033 | incl.
splash protection with shortened neck with increased airflow recommended for 60–1,500 L |
Typical
airflow at 12 mbar: 139 L / h Typical water entry pressure: 0.4 bar |
| F38 EHF | 924 067 | incl.
splash protection with highest airflow recommended for 60–1,500 L |
Typical
airflow at 12 mbar: 225 L / h Typical water entry pressure: 0.3 bar |
| F38 LOCK* EHF | 924 068 | incl.
splash protection with highest airflow recommended for 60–1,500 L |
Typical
airflow at 12 mbar: 225 L / h Typical water entry pressure: 0.3 bar |
| F38 LOCK* SN EHF | 924 034 | incl.
splash protection with shortened neck with highest airflow recommended for 60–1,500 L |
Typical